Proper insulation of chilled water pipe systems.
Chilled water pipe insulation specifications.
It is the ideal choice for insulating mechanical piping systems.
The insulation is tailored to fit for copper and iron pipe applications.
Owens corning ssl ii with asj max fiberglas pipe insulation is molded out of heavy density resin bonded inorganic glass fiberglas that come in one piece 36 914mm long hinged sections.
Exchangers machinery ect and piping which are to be insulated in accordance with the specifications.
Ap armaflex the world s most recognized brand of closed cell foam insulation provides superior protection against thermal losses condensation and moisture accumulation that leads to mold.
We can also personally review your specification and provide feedback.
Jm can help with the specification as well.
3 3 1 2 if insulation is unavailable in thickness shown the next larger thickness commercially available shall be applied.
Astm c547 specification for mineral fiber pipe insulation.
Insulation materials and accessories shall be installed in a workmanlike manner by skilled and experienced workers who are regularly engaged in commercial insulation work.
Insulating chilled water systems requires special attention.
Now offering larger 8 and 10 ids for ease of installation on larger pipe sizes.
Fiberglass pipe insulation on all chilled water and dual cycle pipe systems fittings valves controls and all other necessary items connected into the system subject to condensation or loss of heat when using jm micro lok fiberglass pipe insulation.
Proper installation and maintenance will prevent the design from being compromised.
No wrap pipe.
Naima also has a chilled water insulation guide that has information on writing a chilled water specification.
Naima s guide to insulating chilled water systems offers detailed instructions on performance installation and required specifications.
Chilled water systems from 35f 2c to 65f 18c heating systems steam steam condensate hot water ambient up to 450f 232c.
When piping and equipment.
2 0 role of pipe insulation for chilled water systems 33 f to 60 f 0 5 c to 15 6 c pipe insulation for chilled water systems is specified and installed primarily for process control condensation control and energy conservation.
Ssl ii with asj max fiberglas pipe insulation.
06 01 2012 by christopher curtland faulty design installation or maintenance can cause disaster with chilled water systems selecting the correct materials for the jacket and retarder ensures the pipe is protected.
3 3 1 3 all valves fittings vessel drains and flanges on chilled equipment and piping be fully insulated.